Press the left button, drag the mouse, rotate the cube, see more information

Limit Discounts

Through this webpage, choose online customer service communication, or message board. Leave your needs and get limited time discounts, up to 10% off, saving you a fortune. This discount has an indefinite period, and places are limited on a first-come, first-served basis.

Payment Method

We support various payment methods:
T/T payment
VISA
paypal
MasterCard
Alipay etc
Save time in your buying process.

Certified Product

The company's products have passed multiple national
certifications:
for example:
United States: ASME
EU: CE
Eastern Europe: EAC
Russia: GOST
Singapore: MOMO
etc
Buy products, buy with confidence, use with confidence

Product Type

Domestic hot water and heating series: gas hot water boiler, vacuum hot water boiler, vertical atmospheric pressure hot water boiler, electric hot water boiler Factory use, high temperature steam: wns fuel gas steam boiler, szs water tube steam boiler, vertical steam boiler, electric steam boiler

About Us

FANGKUAI is founded in 1998, which is a clean fuel boiler enterprise integrating R&D, manufacturing, sales and service. In the past 20 years of development and innovation, the company has grown into a global enterprise, and its products have been exported to more than 80 countries including Russia, Mongolia and Thailand, and have established long-lasting cooperative relations with local enterprises!

Contact Us

If you are interested in our company or products, you can contact with us through online consulting, demand table submission, e-mails and telephones. Our staff shall wholeheartedly provide product information, application knowledge and good service for you.

OPEN VESSEL AND STEAM BOILER METHODS FOR ACID

  • Offshore price : $20000-$100000 Get a quote on the right form
  • Minimum order quantity : 1 set :OPEN VESSEL AND STEAM BOILER METHODS FOR ACID
  • Supply Capacity : 10 units/month :OPEN VESSEL AND STEAM BOILER METHODS FOR ACID
  • Manufacturer/Brand : Fangkuai boiler
  • Port : Anyang
  • payment terms : Letter of Credit, Wire Transfer, VISA

Leave Your Message And Get Price!

I need the quotation of , the fuel is , this capacity is , use for . My Name is , my Email is , my WhatsApp is , Please Send the detail information for me!

Popular products

HOT

θrion Gas Fired Steam Boiler

Capacity:1-20t/h

Rated thermal efficiency: 100-104%

Fixed working pressure: ≤1.6MPa

Applicable fuel:natural gas etc.

consult
HOT

Gas(oil) Fired Integrated Hot Water Boiler

Capacity:0.7-14MW

Rated thermal efficiency:96-98%

Fixed working pressure:≤1.25MPa

Applicable fuel:Natural gas, light oil, etc.

consult
HOT

H6 Gas Fired Hot Water Boiler

Capacity:0.7-2.8Mw

Rated thermal efficiency: 97.2-106%

Fixed working pressure:0.1MPa

Applicable fuel:Natural gas, etc.

consult
HOT

T7 Vacuum Hot Water Boilerr

Capacity:2.8-7.0Mw

Rated thermal efficiency:≥105.5%

Fixed working pressure:-0.02MPa

Applicable fuel:Natural gas, etc.

consult
HOT

V6 Gas Fired Hot Water Boiler

Capacity:99Kw

Rated thermal efficiency:97.2-104.4%

Fixed working pressure:1.0MPa

Applicable fuel:Natural gas, etc.

consult
HOT

Electric Steam Boiler

Capacity:0.5-4.0 t/h

Rated thermal efficiency:98%

Fixed working pressure:≤1.25MPa

Applicable fuel:electric energy

consult

Leave us a message

We will send out plans and quotations within five minutes

Name (optional)

Email

Whatsapp

Choose product type

Message

boilermanufactory

Get display discount

boiler
Contact us

Global Sales Hotline:
0086-371-60922096

Email: [email protected]

Voicemail
  • TYPICAL PIPING FOR CONVENTIONAL SINGLE BOILER - …

    boilers. • The by-pass is required for systems designed to operate at flow rate higher than the maximum recom-mended flow rate of the boilers. • This piping method is not recommended for systems designed to operate with return water temperatures less than 140°F. (See recommend piping method for Low Temperature Heating Systems.)Get Price

  • The Cleaning Boiler Scale Methods-EPCB High quality Boiler

    Dec 02, 2016 · The new method of alkali descaling and boiler boiling is basically the same, the difference is should open the boiler inspection hole after boiling, and machinery descaling timely (or high pressure hydraulic machinery), so as the loose scal not to re-harden. 3. Boiler Acid Pickling Descaling. At present among all kinds of cleaning methods, the Get Price

  • CLEAVER-BROOKS

    3.7.2 — Steam Boiler 3-13 3.7.3 — Flushing of Pressure Vessel Interior 3-13 3.8 — Blowdown: Steam Boiler 3-14 3.8.1 — Intermittent Manual Blowdown 3-15 3.8.2 — Continuous Blowdown 3-15 3.8.3 — Frequency of Manual Blowdown 3-15 3.8.4 — Manual Blowdown Procedure 3-16 3.9 — Periodic Inspection 3-17 3.10 — Preparation for Extended Get Price

  • How to Shut Down a Boiler | Get ChemREADY

    6. After every two months of lay-up, open the boiler, inspect the moisture absorbing chemical (replacing it when necessary), and reseal. Open and Dry – The following steps should be taken in laying up a boiler open and dry. 1. After the boiler has cooled, drain the unit completely. 2. Flush thoroughly and inspect.Get Price

  • Part 3 - National Board of Boiler and Pressure Vessel

    The sodium zeolite water softening process is the predominant method of water treatment for boilers operating at low pressures with saturated steam. boiler through the inactive unit is generally sufficient to keep the temperature of the boiler tubes above the acid dew point. Polymer Use for Boilers and Pressure Vessels ; Pressure Vessel Get Price

  • Boilere - Pagina 4 din 5

    Boiler electric Ariston PRO R EVO 80 VTD EUCantitate mare de A.C.M.Termometru imbunatatitTermostat cu supapa de siguranta bipolaraAnod de magneziu… Catre Magazin Boiler termoelectric Ariston PRO R 120 VTS EVO EU, 1800 W, 120 l, serpentina pe partea stanga, izlolatie termica poliuriten, reglare mecanica exterioara, supapa siguranta, protectie Get Price

  • Steam boiler scale inhibitor, sludge (TSS) and TDS control

    [0018] FIG. 2 is a system diagram of a steam boiler scale inhibitor, sludge (TSS) and Total Dissolved Solids (TDS) control, and automatic bottom blow-down management system according to an alternative embodiment of the present invention that is better suited for boilers with pressure vessel codes requiring both fast & slow bottom blow down valves.Get Price

  • Boiler Layup Procedures - Water Technology Report

    Jul 24, 2017 · Boilers must be stored under carefully control conditions to prevent rust formation, pitting-type corrosion and general deterioration of boiler metal. Two methods for boiler lay-up are recognized as effective: (1) dry lay-up and (2) wet lay-up. Dry lay-up is recommended for boilers that will be out of service for 6 months or longer.Get Price

  • US1759615A - Treatment of steam-boiler water - Google Patents

    US1759615A US152730A US15273026A US1759615A US 1759615 A US1759615 A US 1759615A US 152730 A US152730 A US 152730A US 15273026 A US15273026 A US 15273026A US 1759615 A US1759615 A US 1759615A Authority US United States Prior art keywords steam boiler water boiler water waters Prior art date Liming Legal status (The legal status is an …Get Price

  • An Overview of Air Venting in Steam Boilers - Boilers and

    Dec 22, 2021 · A drop in the output of the steam boiler; Condensate with air bubbles. Corrosion in the steam boiler. Air Removal from Steam Boilers: Device for Air Vent: Automatic devices are the most effective method of air removal. With the blend of air with steam reducing the mix temperature, it facilitates the thermostatic device to vent the steam boiler.Get Price

  • DEP Boiler | PDF | Boiler | Furnace

    Whether acid cleaning is proposed or not, suitable connections on the boiler such as nozzles etc. shall be provided if an acid cleaning process is desired at a future date. All equipment necessary for the pre-start-up chemical cleaning, such as pump, tanks, heaters, valves, piping and chemicals shall be supplied by the Contractor, see DEP 70.10 Get Price

  • Comparison Of Pressure Vessel Codes Asme Section Viii And

    Oct 24, 2021 · Read Book Comparison Of Pressure Vessel Codes Asme Section Viii And to ASME VIII-1 and VIII-2; Hot water heaters and boilers to ASME I and IV; Piping to B31.1, B31.3, B31.5 and othersPressure vessels, which range from small bottles of a few centimeters in diameter to large storage tanks of several meters in diameter, are in widespread use in Get Price

  • Boiler Water Conditioning | PDF | Steam | Boiler

    A Boiler is a closed vessel inside which water is stored, heated and circulated, either as hot water, steam or superheated steam for the purpose of heating, powering and/or producing electricity. The furnace of the boiler is where the fuel and air are introduced to combust; fuel/air mixtures are normally introduced into the furnace by using burners, where the flames are formed.Get Price

  • ASME Boiler and Pressure Vessel Code

    traction type boilers, but not locomotive and high-temperature water boilers, nuclear power-plant boilers (see Section XI), heating boilers (see Section VI), pressure vessels, or marine boilers. Guidelines are also provided for operation of auxiliary equipment and appliances that affect the safe and reliable operation of power boilers.Get Price

  • Industrial Steam Boiler Scaling Causes, Hazards and Solutions

    Feb 03, 2021 · First, mechanical descaling method. After the boiler stops, put off the furnace water, rinse with clean water, you can use hammer, shovel, steel wire brush and electric pipe washer and other tools for descaling.This method is relatively simple, and is mostly used for small cast iron boilers with simple scaling.But the labor intensity, descaling effect is poor, easy to …Get Price

  • Fatty acid distillate as an alternative boiler fuel

    Nov 01, 2021 · Fatty Acid Distillate (FAD) is produced when the oil is heated to high temperature (200–250 °C) under vacuum to remove the odour causing components. The volatile components are separated from the oil and then condensed in a separate collection chamber or vessel (De Greyt, 2021). This volatile fraction is known as Fatty Acid Distillate and Get Price

  • (PDF) VGB-Standard Feed Water, Boiler Water - Academia.edu

    This VGB-Standard supports the operator of water-steam cycles in power plants and related branches in selecting and judging suitable water regimes with respect to a safe and economically sound operation of the power plant for a long period of time.Get Price

  • Boiler Layup: Procedures And Pitfalls - Rasmussen Mechanical

    Jan 31, 2022 · For steam boilers, after pressure has dropped to 10-25 PSIG, open the boiler vent to prevent pulling a vacuum on the boiler. (always refer to your manual) Once the unit has dropped below 200 degrees, it's ready to be drained. Draining does not have to be immediate.Get Price

  • Methods of Detecting Water Level in Steam Boilers | Spirax

    Methods of Detecting Water Level in Steam Boilers. On a steam raising boiler there are three clear applications for level monitoring devices: Level control - To ensure that the right amount of water is added to the boiler at the right time. Low water alarm - For safe boiler operation, the low water alarm ensures that the combustion of fuel does Get Price

  • How to Chemically Clean Steam Boilers | Chardon Laboratories

    pretreatment is explored in this study for open vessel and steam boiler methods in terms of agar production at wet conditions. For the selection of acids the very strong (H 2 SO 4), strong (HCl) and weak acid (CH 3 COOH) were used and CH 3 COOH was selected. Furthermore, the strength of CH 3 COOH was optimized at 1%. The steam boiler treatmentGet Price

  • How To Clean Scale From Your Boiler - Chardon Labs

    Isolate the boiler by closing the gate valves as close to the vessel as possible. Keep the top manhole open to allow for periodic inspections during the cleaning. Estimate the total number of gallons of water the vessel section will contain. Calculate the amount of initial acid to use to get a 1-5% concentration of Chardon's Scalzo in the boiler.Get Price

  • Rust Preventives for Boiler | Pressure Vessel | Hydrotesting

    Wet and dry layup and mothballing corrosion inhibitors for boilers, industrial cooling systems (additive for coolant). Stop rust in close or open loop water and water + glycol systems. If your pressure vessels has scale or rust on tube surface, or inside boiler tubes, we can help treat the problem. Boiler rust prevention.Get Price

  • Boiler termoelectric Ariston Pro 1 R VTS 100L, 1800W

    Descriere. Boiler termoelectric Ariston Pro 1 R VTS 100L, 1800W, serpentina pe partea stanga Boiler termoelectric Ariston Pro 1 R VTS 100L, 1800W, serpentina pe partea stanga PERFORMANTE DE TOPTehnologia WaterPlus*: pana la 16%** mai multa apa calda disponibilaSerpentina de schimb suplimentara pentru integrare cu un sistem de incalzire …Get Price

  • Equipment and control | Bosch steam boiler planning

    Equipment and control. The minimum requirements for operation and the safety equipment of steam boilers are set out in EN 12953-6. This includes the primary shut-off valves in the pipework, the safety equipment to safeguard against pressure exceedance and water shortage, heating equipment and all valves and measuring devices required for operation and control.Get Price

  • Low Pressure Boilers 4th Edition Steingress

    Myristic acid | C14H28O2 - PubChem Specification for High Tensile Strength Carbon-Silicon Steel Plates for Boilers and Other Pressure Vessels, ASTM 212, ASTM International, West Conshohocken, PA. Available at: .astm.org. ASTM (2006), Standard Test Methods for Determining Effects of Large Hydrocarbon Pool Fires on Structural Members and Get Price

  • Boiler Archives - Page 6 of 11 - Boilers and Steam Boiler

    Dec 15, 2021 · Boilers are an integral asset in the process and manufacturing industries globally. For the uninitiated, boilers are closed chambers that generate steam from water and heat through the combustion of fuels. Boilers mainly include drum/shell, multiple tubes, …Get Price

  • BOILERS - Virginia Tech

    the total amount of acid or alkali in a sample, employ a titration method using an alkali or acid solution of known concentration. 7 The proper pH of feedwater for boilers ranges from 7.5 to 9.5, and that of blowdown water from 10.2 to 11.5. Improper pH induces corrosion. AsGet Price

  • Schema montaj centrala lemne - fiercare centrala termica

    Mar 30, 2011 · Schema cazan lemne cu vas puffer duration. Racordare tur retur la sistemul de incalzire. Inainte de a folosi o schema de montaj centrala termica pe gaz haide sa vedem cum o alimentam electric. Accesorii armaturi produse montaj. Manual de utilizare boiler ariston pro plus 50 specificatii caracteristici generale tip produs boiler electric.Get Price

  • Controlling TDS in the Boiler Water - Spirax Sarco

    Conventional shell boilers are normally operated with the TDS in the range of 2 000 ppm for very small boilers, and up to 3 500 ppm for larger boilers, provided the: Boiler is operating near to its design pressure. Steam load conditions are not too severe. Other boiler water conditions are correctly controlled.Get Price

  • What is a Boiler ? & its types - Chemical Engineering World

    May 27, 2019 · What is Boiler:-A boiler is outlined as "A closed vessel during which water or different liquid is heated, steam or vapor is generated, steam is super heated, or any combination therefrom, besieged or vacuum, to be used external to itself, by the direct application of energy from the combustion of fuels, from electricity or energy ".A Brief Introduction Get Price

Discount
7X24 Online