Press the left button, drag the mouse, rotate the cube, see more information

Limit Discounts

Through this webpage, choose online customer service communication, or message board. Leave your needs and get limited time discounts, up to 10% off, saving you a fortune. This discount has an indefinite period, and places are limited on a first-come, first-served basis.

Payment Method

We support various payment methods:
T/T payment
VISA
paypal
MasterCard
Alipay etc
Save time in your buying process.

Certified Product

The company's products have passed multiple national
certifications:
for example:
United States: ASME
EU: CE
Eastern Europe: EAC
Russia: GOST
Singapore: MOMO
etc
Buy products, buy with confidence, use with confidence

Product Type

Domestic hot water and heating series: gas hot water boiler, vacuum hot water boiler, vertical atmospheric pressure hot water boiler, electric hot water boiler Factory use, high temperature steam: wns fuel gas steam boiler, szs water tube steam boiler, vertical steam boiler, electric steam boiler

About Us

FANGKUAI is founded in 1998, which is a clean fuel boiler enterprise integrating R&D, manufacturing, sales and service. In the past 20 years of development and innovation, the company has grown into a global enterprise, and its products have been exported to more than 80 countries including Russia, Mongolia and Thailand, and have established long-lasting cooperative relations with local enterprises!

Contact Us

If you are interested in our company or products, you can contact with us through online consulting, demand table submission, e-mails and telephones. Our staff shall wholeheartedly provide product information, application knowledge and good service for you.

rule of thumb boiler efficiency

  • Offshore price : $20000-$100000 Get a quote on the right form
  • Minimum order quantity : 1 set :rule of thumb boiler efficiency
  • Supply Capacity : 10 units/month :rule of thumb boiler efficiency
  • Manufacturer/Brand : Fangkuai boiler
  • Port : Anyang
  • payment terms : Letter of Credit, Wire Transfer, VISA

Leave Your Message And Get Price!

I need the quotation of , the fuel is , this capacity is , use for . My Name is , my Email is , my WhatsApp is , Please Send the detail information for me!

Popular products

HOT

θrion Gas Fired Steam Boiler

Capacity:1-20t/h

Rated thermal efficiency: 100-104%

Fixed working pressure: ≤1.6MPa

Applicable fuel:natural gas etc.

consult
HOT

Gas(oil) Fired Integrated Hot Water Boiler

Capacity:0.7-14MW

Rated thermal efficiency:96-98%

Fixed working pressure:≤1.25MPa

Applicable fuel:Natural gas, light oil, etc.

consult
HOT

H6 Gas Fired Hot Water Boiler

Capacity:0.7-2.8Mw

Rated thermal efficiency: 97.2-106%

Fixed working pressure:0.1MPa

Applicable fuel:Natural gas, etc.

consult
HOT

T7 Vacuum Hot Water Boilerr

Capacity:2.8-7.0Mw

Rated thermal efficiency:≥105.5%

Fixed working pressure:-0.02MPa

Applicable fuel:Natural gas, etc.

consult
HOT

V6 Gas Fired Hot Water Boiler

Capacity:99Kw

Rated thermal efficiency:97.2-104.4%

Fixed working pressure:1.0MPa

Applicable fuel:Natural gas, etc.

consult
HOT

Electric Steam Boiler

Capacity:0.5-4.0 t/h

Rated thermal efficiency:98%

Fixed working pressure:≤1.25MPa

Applicable fuel:electric energy

consult

Leave us a message

We will send out plans and quotations within five minutes

Name (optional)

Email

Whatsapp

Choose product type

Message

boilermanufactory

Get display discount

boiler
Contact us

Global Sales Hotline:
0086-371-60922096

Email: [email protected]

Voicemail
  • Improve Your Boiler's Combustion Efficiency

    attainable. An often-stated rule of thumb is that boiler efficiency can be increased by 1% for each 15% reduction in excess air or 40°F reduction in stack gas temperature. Suggested Actions Boilers often operate at excess air levels higher than the optimum. Periodically monitor flue gas composition and tune your boilersGet Price

  • Improve Your Boiler's Combustion Efficiency - Energy

    Improve Your Boiler's Combustion EfficiencyGet Price

  • Improving Energy Efficiency of Boiler Systems

    effect on boiler efficiency. Most efficiency calculations use an ambient temperature of 80°F and a relative humidity of 30%. Efficiency changes more than 0.5% for every 20°F change in ambient temperature. Changes in air humidity would have similar effects; the more the humidity, the lower will be the efficiency.Get Price

  • WSU Energy Program > Home

    Load management measures, including optimal matching of boiler size and boiler load, can save as much as 50% of a boiler's fuel use. Rule of Thumb Energy Savings An upgraded boiler maintenance program including optimizing air-to-fuel ratio, burner maintenance, and tube cleaning, can save about 2% of a facility's total energy use with an Get Price

  • How to Calculate Boiler Economizer Efficiency

    How to Calculate Boiler Economizer Efficiency Boiler Economizer Calculation. A generally accepted "rule of thumb" is that about 5% of boiler input capacity can be recovered with a properly sized economizer. A higher percentage can be recovered with a Flue Gas Condenser, assuming there is enough cold water to condense all of the flue gas Get Price

  • Best Methods To Improve Boiler Efficiency - Ganeshas

    Boiler efficiency may be boosted by 1% for every 15% decrease of surplus air, according to a common rule of thumb. The boiler's burning efficiency will be maximized and heat loss up the stack will be minimized with a correctly built O2 trim system. To keep extra air at optimum levels, make sure the boiler control systems are operating Get Price

  • Boiler Stack Loss and effect of Excess Air

    As a rule of thumb, boiler efficiency increases 1 percent for every 15 percent reduction in excess air. Operators should be careful to prevent the excess air rate from dropping too low, since this can result in heavy buildup of carbon monoxide and possibly even smoke.Get Price

  • Rules of Thumb

    Rules of Thumb, such as those contained in this publication, can provide extremely useful guidance to inform the early stages of this process, such as briefing, feasibility studies and concept design. This may be in the assessment of space and weight requirements, the Figure 7: Gas fired boiler plantroom – area and height requirements 12 Get Price

  • Replacement boiler sizing based on past usage

    Mar 23, 2017 · I'm looking for some reassurance and validation before I pull the trigger on an expensive purchase. I currently have a 40+ year old, 137,000 BTUh oil boiler that is getting long in the tooth due to substantial corrosion. I have done many efficiency upgrades to my home. I am very interested in replacing the boiler with an electric boiler as the boiler I have now short …Get Price

  • rule of thumb | Hristo Petrov USA - Fort Wayne - Indiana

    Aug 13, 2010 · Rules-of-thumb usage rules: 1. Schematic design to find orders-of-magnitude. 2. As a check to a load model or a cost take-off. 3. Costs increase each year, usually 5% 4. Use with caution . Hydronics HWS/R for non-condensing boilers: 180˚F/150˚F (30º Δ is conservative, could be 40º or 50º Δ)Get Price

  • Improve Your Boiler's Combustion Efficiency

    often stated rule of thumb is that boiler efficiency can be increased by 1% for each 15% reduction in excess air or 40°F reduction in stack gas temperature. Example A boiler operates for 8,000 hours per year and consumes 500,000 MMBtu of natural gas while producing 45,000 lb/hr of 150 psig steam. Stack gas measurements indicate anGet Price

  • How to Calculate Boiler Economizer Efficiency

    How to Calculate Boiler Economizer EfficiencyGet Price

  • Boiler effeciency loss over time? - DoItYourself.com

    Jan 22, 2009 · Boilers - Home Heating Steam and Hot Water Systems - Boiler effeciency loss over time? - I am wondering if there is a rule of thumb about a boiler's loss of efficiency over time? I have cast-iron 1988 Weil-McLain 200,000 BTU output gas boiler. I am considering replacing it purely for efficiency's sake -- it runsGet Price

  • Hydronic Heating Buffer Tanks Part 2 - Sizing | R.L. Deppmann

    Nov 16, 2020 · T is the minimum suggested boiler firing time. This time is meant to keep the boiler from cycling on and off too frequently and is determined by the boiler manufacturer. A "rule of thumb" is no more than 6 starts per hour so 60/6 = 10 minutes. Q B is the BTUH boiler output at the minimum fire of the boiler.Get Price

  • radiator efficiency - Technical - Antique Automobile Club

    Apr 29, 2021 · Allow me to give a similar 'rule of thumb.' In power generation one can calculate/estimate a plant heat rate ( typically very hard to do - many many variables) by using the turbine heat rate ( very well known) divided by the station service and boiler efficiency -- it gets one close. ( THR/((1-station service (%))*(blr eff (%)). Simple!Get Price

  • boiler sizing rule of thumb – Industrial Boiler Supplier

    May 08, 2020 · Safe operating speed of boiler feed pumps is 55–60% of rated speed. Boiler feed pumps suction strainer pressure drop should be 0.04 to 0.06 …Get Price

  • Power 101: Improving the Performance of Boiler Auxiliaries

    Dec 01, 2010 · The increase in boiler efficiency is significant: a 25F change in flue gas temperature leaving the APH results in an approximately 1% (relative) As a rule of thumb, approximately two-thirds of Get Price

  • Avoiding Stack Losses and Excess Air - Facilities

    Jul 01, 2008 · This tactic helps ensure safe boiler operation. Technicians also should keep excess air levels as low as possible — about 15 percent excess air, equivalent to 3 percent oxygen — to reduce the quantity of air to be heated and exhausted at the stack. As a rule of thumb, boiler efficiency increases 1 percent for every 15 percent reduction in Get Price

  • Flue Temperature - an overview | ScienceDirect Topics

    The improvement in boiler efficiency can be determined by measuring the stack flue gas temperature. The stack gas temperature should decrease when the turbulators are installed. As a rule of thumb, a 2.5% increase in the boiler efficiency is expected for each 50°C (90°F) decrease in the stack flue gas temperature. •Get Price

  • O2 Trim for Increased Boiler Efficiency & Emissions

    Oct 01, 2021 · Boiler efficiency is affected by the excess air concentration in the flue gas. The rule of thumb is that for every 5% more excess air, boiler efficiency decreases by 0.5%. If not adjusted, the boiler stack can vary by at least 2% O2 (i.e., if normal operation is 3% O2, it can increase to 5% O2 on a cold day).Get Price

  • How To Choose a New Boiler - Bob Vila

    Jan 28, 2021 · An easy rule-of-thumb for BTU requirements is to figure that you need about 50 BTU per square foot of interior space in a cold climate; 35 BTU per square foot in a moderate climate; and 20 BTU per Get Price

  • 5 Hidden Rules to Improve Steam System Efficiency

    Oct 30, 2020 · For every 10 °C increase in flue gas temperature, boiler efficiency decreases by 0.45% and vice versa. 26. For every 100 kcal/kg increase in GCV of coal, boiler (TG) efficiency increases by 0.36% and vice versa. 27. Boiler peak load = Boiler MCR X 110%. Minimum possible duration of boiler peak load is 30 minutes/shift. 28.Get Price

  • Boiler Rule of Thumb 1 - contractorselling.com

    Boiler Rules of Thumb WATER TEMPERATURE APPLICATIONS INFLOOR RADIATION 120F TO 150F CAST IRON RADIATORS 140F TO 180F COPPER FIN CONVECTORS 180F TO 230F Net BTUH Load = Flow Rate 10,000 Flow Rate 1/2" 3/4" 1" 1 1/4" Maximum Flow Rate Maximum Flow Rate 1 1/2 gpm 4 gpm 8 gpm 14 gpm Pipe Size (Copper) 1/2" 3/4" 1" Get Price

  • (PDF) Rules of Thumb Guidelines for building services …

    As a rule of thumb, a 2.5% increase in the boiler efficiency is expected for each 50°C (90°F) decrease in the stack flue gas temperature. Insulate the jacket of the boiler to reduce heat losses. The improvement of the boiler efficiency depends on the surface temperature.Get Price

  • Boiler Efficiency - an overview | ScienceDirect Topics

    Boiler Efficiency - an overview | ScienceDirect TopicsGet Price

  • Understanding Firetube Boiler Efficiency Ratings

    emissions, and turndown. While some boilers may perform well on one or two of the parameters, it may be at the expense of the third. It's a good rule of thumb to compare boiler efficiency ratings with actual excess air levels throughout the 10:1 turndown range. For gas-firing boilers, ask for efficiency charts fromGet Price

  • Thumb rules for power plant - Power plant and calculations

    Boiler Efficiency - an overview | ScienceDirect TopicsGet Price

  • Tips to Improve Boiler Combustion Efficiency

    An often-stated rule of thumb is that boiler efficiency can be increased by 1% for each 15% reduction in excess air or 40°F reduction in stack gas temperature. Example A boiler operates for 8,000 hours per year and annually consumes 500,000 million Btu (MMBtu) of natural gas while producing 45,000 lb/hour of 150-psig steam.Get Price

  • Some thumb rules about Boiler – Sameer's Blog

    Power plant and calculations: Thumb rules for power plantGet Price

  • Principals of Condensing Boiler System Design

    boiler efficiency increases dramatically down to about 80˚F (27˚C), which is the boiler EWT at which the boiler is rated. Delta-T dictated by a rule of thumb. Consider another example, selection of an air heating coil, summarized in Table 2. A 20˚F (11˚C) delta-T on the water side is often used to size heating coils. High-performance Get Price