Press the left button, drag the mouse, rotate the cube, see more information

Limit Discounts

Through this webpage, choose online customer service communication, or message board. Leave your needs and get limited time discounts, up to 10% off, saving you a fortune. This discount has an indefinite period, and places are limited on a first-come, first-served basis.

Payment Method

We support various payment methods:
T/T payment
VISA
paypal
MasterCard
Alipay etc
Save time in your buying process.

Certified Product

The company's products have passed multiple national
certifications:
for example:
United States: ASME
EU: CE
Eastern Europe: EAC
Russia: GOST
Singapore: MOMO
etc
Buy products, buy with confidence, use with confidence

Product Type

Domestic hot water and heating series: gas hot water boiler, vacuum hot water boiler, vertical atmospheric pressure hot water boiler, electric hot water boiler Factory use, high temperature steam: wns fuel gas steam boiler, szs water tube steam boiler, vertical steam boiler, electric steam boiler

About Us

FANGKUAI is founded in 1998, which is a clean fuel boiler enterprise integrating R&D, manufacturing, sales and service. In the past 20 years of development and innovation, the company has grown into a global enterprise, and its products have been exported to more than 80 countries including Russia, Mongolia and Thailand, and have established long-lasting cooperative relations with local enterprises!

Contact Us

If you are interested in our company or products, you can contact with us through online consulting, demand table submission, e-mails and telephones. Our staff shall wholeheartedly provide product information, application knowledge and good service for you.

The shell diameter and length of locomotive boiler are

  • Offshore price : $20000-$100000 Get a quote on the right form
  • Minimum order quantity : 1 set :The shell diameter and length of locomotive boiler are
  • Supply Capacity : 10 units/month :The shell diameter and length of locomotive boiler are
  • Manufacturer/Brand : Fangkuai boiler
  • Port : Anyang
  • payment terms : Letter of Credit, Wire Transfer, VISA

Leave Your Message And Get Price!

I need the quotation of , the fuel is , this capacity is , use for . My Name is , my Email is , my WhatsApp is , Please Send the detail information for me!

Popular products

HOT

θrion Gas Fired Steam Boiler

Capacity:1-20t/h

Rated thermal efficiency: 100-104%

Fixed working pressure: ≤1.6MPa

Applicable fuel:natural gas etc.

consult
HOT

Gas(oil) Fired Integrated Hot Water Boiler

Capacity:0.7-14MW

Rated thermal efficiency:96-98%

Fixed working pressure:≤1.25MPa

Applicable fuel:Natural gas, light oil, etc.

consult
HOT

H6 Gas Fired Hot Water Boiler

Capacity:0.7-2.8Mw

Rated thermal efficiency: 97.2-106%

Fixed working pressure:0.1MPa

Applicable fuel:Natural gas, etc.

consult
HOT

T7 Vacuum Hot Water Boilerr

Capacity:2.8-7.0Mw

Rated thermal efficiency:≥105.5%

Fixed working pressure:-0.02MPa

Applicable fuel:Natural gas, etc.

consult
HOT

V6 Gas Fired Hot Water Boiler

Capacity:99Kw

Rated thermal efficiency:97.2-104.4%

Fixed working pressure:1.0MPa

Applicable fuel:Natural gas, etc.

consult
HOT

Electric Steam Boiler

Capacity:0.5-4.0 t/h

Rated thermal efficiency:98%

Fixed working pressure:≤1.25MPa

Applicable fuel:electric energy

consult

Leave us a message

We will send out plans and quotations within five minutes

Name (optional)

Email

Whatsapp

Choose product type

Message

boilermanufactory

Get display discount

boiler
Contact us

Global Sales Hotline:
0086-371-60922096

Email: [email protected]

Voicemail
  • Locomoive Boiler shell types - rypn.org

    Feb 15, 2007 · Of course, there are a number of more recently constructed or rebuilt locomotives that have new welded boilers in this post-steam era period. For the record, Kanawha #2789 was built for the C&O by ALCO in 1947. Unfortunately, its four sister engines built at the same time (numbers 2785 - 2788) were all scrapped.Get Price

  • BOILER SPECIFICATION CARD Locomotive No Boiler No Date

    Make working sketch here or attach drawing of longitudinal and circumferential seams used in shell of boiler, indicating on which courses used and give calculated efficiency of weakest longitudinal seam.Get Price

  • Multiple-Choice Questions or Objective Type Questions on

    Mar 11, 2021 · The diameter of the flue tubes of a Lancashire boiler is ____times that of shell. 0.2; 0.4 ; 0.6; 0.8; The diameter of the flue tubes of a Cornish boiler is ____times that of shell. 0.2; 0.4 0.6 ; 0.8; The locomotive boiler has____ numbers of fire tubes and ____ numbers of water tubes. 157,34 ; 127,14; 117,04; 17,04Get Price

  • Mechanical Engineering-Steam Boilers - All Exam Review

    Jun 12, 2017 · 92. Locomotive boiler is of the following type (a) multitubular (b) horizontal (c) internally fired (d) mobile (e) all of the above. Ans: e. 93. The shell diameter and length of locomotive boiler are (a) 1.5 m, 4 m (b) 1.5 m, 6 m (c) 1 m, 4 m (d) 2 m, 4 m (e) 1.5 m, 8 m. Ans: a. 94. The diameters of fire tubes and superheaer tubes in locomotive Get Price

  • The shell diameter and length of locomotive boiler are

    The shell diameter and length of locomotive boiler are. The shell diameter and length of locomotive boiler are. 1.5 m, 4 m. 1.5 m, 6 m. 1 m, 4 m. 2 m, 4 m. Answer is: 1.5 m, 4 m. Explanation: Image: For More Pressure Vessels MCQ Click …Get Price

  • Steam Boilers, Engines, Nozzles and Turbines MCQs

    The shell diameter and length of locomotive boiler are. A. 1.5 m, 4 m. B. 1.5 m, 6 m. C. 1 m, 4 m. D. 2 m, 4 m. Explanation : Explanation Not Provided. See Details . Question 290. The Locomotive boiler has. A. 137 fire tubes and 44 superheated tubes. B. 147 fire tubes and 34 superheated tubes. C. 157 fire tubes and 24 superheated tubes. D.Get Price

  • The shell diameter and length of locomotive boiler are

    The shell diameter and length of locomotive boiler are A. 1.5 m, 4 m B. 1.5 m, 6 m C. 1 m, 4 m D. 2 m, 4 m Answer: Option A The expansion of steam in a nozzle follows A. Carnot cycle B. …Get Price

  • Power Plant Enginering - Mechanical - grabSTUDY

    The shell diameter and length of locomotive boiler are A.1.5 m, 4 int B.1.5 m, 6 m C.1 m, 4m D.2 m, 4 m . View Answer. Discuss in Forum . 89. The diameters of fire tubes and superheaer tubes in locomotive boiler are A.47.5 mm, 130 mm B.32.5 mm, 180 mm C.65.5 mm, 214-mm D.24.5 mm, 65 mm . View Answer. Discuss in Forum . 90. The water -tubes in a Get Price

  • Locomotive Boiler : Construction, Working, Advantages and

    Feb 12, 2019 · Locomotive Boiler: Construction: In this boiler so many components are involved. All the components are mention in the below figure. Here we will discuss the main components. Shell. It has the shell or barrel in which the fire tubes are placed. Shell is filled with water. Standard dimensions of this boiler are, shell diameter is 8.5 and length Get Price

  • The length of shell of a Locomotive boiler is - Examveda

    The length of shell of a Locomotive boiler is a) 1 m b) 2 m c) 3 m d) 4 m. In a uniflow engine. A. Steam enters and exhausts through the same port. B. Steam enters at …Get Price

  • The diameter of flue tube in a Cornish boiler is

    In a glass rube type water indicator for a boiler, one end of the tube is connected to water space and the other end is connected to _____ Q: The draught produced by a steam jet issuing from a nozzle placed in the ashpit under the fire grate of the furnace is called ___________Get Price

  • Ablesson 1 Description of Steam Locomotive Boiler …

    LOCOMOTIVE BOILERS are made up of a cylindrical portion THE FIREBOX consists of an outer and inner shell and the foundation ring. The outer shell is made up of the followina p] of the grates into the boiler barrel and varies in length accord to the size and capacity of the boiler.Get Price

  • What Is A Locomotive Boiler And How Does It Work? | IQ Mech

    Mar 10, 2021 · Barrel/ shell diameter- 8.5 m; Applications of a Locomotive Boiler. Locomotive boilers are generally used in Railways and Marines. Apart from that these boilers are used in Steam Rollers, Traction Engines, and Portable Engines. How does a Locomotive Boiler. The solid fuel e.g. coal is fed through the fire hole and burns on a base-like plate e.g Get Price

  • Fire-tube boiler - Wikipedia

    In the locomotive-type boiler, fuel is burnt in a firebox to produce hot combustion gases. The firebox is surrounded by a cooling jacket of water connected to the long, cylindrical boiler shell. The hot gases are directed along a series of fire tubes, or flues, that penetrate the boiler and heat the water thereby generating saturated ("wet") steam.Get Price

  • Question is ⇒ Which of the following is a water tube

    ⇒ The shell diameter and length of locomotive boiler are 1.5 m, 4 m 1.5 m, 6 m 1 m, 4 m 2 m, 4 m ⇒ While steam expands in turbines, theoretically the entropy remains constant increases decreases behaves unpredictably ⇒ Pulverized fuel is used for better burning more calorific value less radiation loss medium sized unitsGet Price

  • The shell diameter and length of locomotive boiler are

    A locomotive boiler is a multi-tubular, horizontal, internally fired, and mobile boiler. It consists of a shell or barrel having 1.5 m diameters and 4 m in length. Features and characteristics of Locomotive boiler. Internally fired, Horizontal, Multi-tubular, Fire tube, Natural circulation, Artificial draft, Portable boilerGet Price

  • 250+ TOP MCQs on Steam Generators – Fire Tube Boilers – 2

    a) The length of its shell is about 10 m. b) It has a steam capacity of 12000 kg/hr. c) It is a water tube boiler. d) Its efficiency is about 50 to 70%. Answer: d. Clarification: The efficiency of Lancashire boiler lies in the range of 50 to 70%. The length of the boiler shell is 7 to 9 m and its diameter ranges from 2 to 3 m.Get Price

  • Question is ⇒ Locomotive type' boiler is, Options are ⇒ (A

    ⇒ The shell diameter and length of locomotive boiler are 1.5 m, 4 m 1.5 m, 6 m 1 m, 4 m 2 m, 4 m ⇒ Which device is used in thermal power plants to reduce level of pollution induced draft fan smoke meter chimney precipitator ⇒ While steam expands in turbines, theoretically the entropy remains constant increases decreases behaves unpredictablyGet Price

  • Engines and Rolling Stock | Tinkerbell Boiler Dimensions

    Apr 30, 2012 · The locomotive boiler has the same outer shell dimensions (12.75" diameter, 24.5" long, 10mm wall), but typically has a firebox protruding 3-3.5" below the barrel, and is 12" long (outside). There is no 'standard' locomotive boiler, you would have to speak to one of the boiler manufacturers to see exactly what they would build for you.Get Price

  • Locomotive Boilers and Engines

    The present practice is to use tubes of from 2 to 21¼ inches in diameter. They vary in length from about 15 to 20 feet, the length depending on the construction of the boiler and locomotive as a whole. The tubes are supported at each end by letting them extend through the tube sheets. It is in the setting of the tubes that great care should be Get Price

  • The shell diameter and length of locomotive boiler are

    MCQs: The shell diameter and length of locomotive boiler are? - (A) 1.5 m, 4 m - (B) 1.5 m, 6 mGet Price

  • The shell diameter and length of locomotive boiler are

    Steam boilers, Engines, Nozzles and Turbines - Section 4 Steam Boilers, Engines, Nozzles and Turbines - Section 5 Question: The shell diameter and length of locomotive boiler areGet Price

  • Largest Diameter Boiler? | O Gauge Railroading On Line Forum

    Feb 10, 2010 · According to The Locomotives that Baldwin Built by Fred Westing, the Alco Big Boy's boiler was 95" in diameter. The Western Pacific had some Liming-2's and the DM&IR had some Liming-4's that each had boilers 104" in diameter. I have seen claims that the Virginian Liming-2's had the largest boiler diameter (Wikipedia says 119"), but I don't know of a published …Get Price

  • Railway Preservation News • View topic - 3/4" Studs in Boiler

    Jan 10, 2018 · What is the correct tap diameter for 3/4" studs in a locomotive boiler per code? The only answer is "it depends". If the major diameter of the stud is 3/4 at the outside surface of the boiler, its minor diameter at the inside surface of the shell will depend on the thickness of the shell, and the thread form of the tap.Get Price

  • Shell Boilers | Spirax Sarco

    Disadvantages of shell boilers: The package principle means that approximately 27 000 kg/h is the maximum output of a shell boiler. If more steam is required, then several boilers need to be connected together. The large diameter cylinders used in the construction of shell boilers effectively limit their operating pressure to approximately 27 bar.Get Price

  • Steam Boilers, Engines, Nozzles & Turbines Mcqs

    MCQs: In locomotive boiler, maximum steam pressure is limited to_____? Category: Mechanical Engineering Questions, Published by: T-Code Scripts. MCQs: The shell diameter and length of locomotive boiler are_____? Category: Mechanical Engineering Questions, Published by: T-Code Scripts . MCQs: Get Price

  • Staying for Construction of Boilers - stay and stays

    In the ordinary fire-tube boiler the principal surfaces stayed are: the flat ends, crown sheets, flat sides of locomotive boilers and combustion chambers of cylindrical marine boilers. In t h e case of most marine or Scotch boilers, the diameter is large compared to the length ; hence the flat surface is considerable, and needs careful staying.Get Price

  • The length of shell of a Locomotive boiler is

    In a boiler, feed water supplied per hour is 205 kg while coal fired per hour is 23 kg. The net enthalpy rise per kg of water is 145 kJ. If the calorific valve of the coal is 2050 kJ/kg, then the boiler efficiency will be; The diameter of flue tube in a Cornish boiler is _____ that of the shell. The draught in locomotive boilers is produced by aGet Price

  • Steam boiler objective questions (mcq) and answers

    In locomotive boiler,maximum steam pressure is limited to.. A. 1 kg/cm 2. B. 5 kg/cm 2. 12. The difference between cornish boiler and lancashire boiler is .. A. Former is fire tube type and latter is water tube The shell diameter and length of locomotive boiler are.. A. 1.5 m,4 m. A. 1.5 m,6 m. C. 1 m,4 m. D. 2 m,4 m. View Get Price

  • Locomotive Boilers and Engines

    Table of Contents; Page 130; Page 135; Index Cylinders. The formula commonly used in determining the thickness of boiler shells, circular tanks, and cylinders is. where t = thickness of cylinder wall in inches p = pressure in pounds per square inch d = diameter of cylinder in inches f = safe fiber stress which for cast iron is usually taken at 1500 pounds per square inchGet Price

Discount
7X24 Online